Omnes Categoriae
Dc reactor
Domum> Dc reactor

Dc Reactor Reactor Lævigator

Parametri technici
Voltagium operationis ratum: 380V-1140V/50Hz
2. Currentio operationis ratus: 3A ad 2000A/40℃
3. Fortitudo electrica: Nullus disruptio arcus in 3000VAC/50Hz/5mA/10s pro nucleo et involucro
4. Resistenta izolării: valoarea rezistenței de izolare a surselor de 1000VDC este ≥100MΩ
5. Zgomot al reactorului: mai mic de 65dB (testat la o distanță orizontală de 1 metru de la reactor)
6. Grad de protecție: IP00
7. Clasa de izolare: clasa F sau mai sus

Introductio

Rerum Technicarum Summarium Reactoris DC (Reactor Laevigandi)

Functiones Principales

Compression Harmonica: Finit undulationem AC (20-150Hz) in parte DC (typicum ≤10% a cursu praefinito).

Melioratio Factoris Potentiae: Augeit input PF ab 0.75 ad 0.95 (operatione 50Hz).

Continuitas Cursus: Servat minimum cursum criticum ne rectificator interruptus fiat.

Specificationes Claves

Inductio: 1–30 mH (varies cum gradu potentiae inverteris)

Gradus Curretis: 100–3000 A

Decessio Voltii: <2% voltii accepti

Application missiones

Classis A (Installatio Obligatoria):

Reticulum THDv 5% aut capacitas curtus-circuitus 40× rating inversoris

Systemata multi-inversoria parallela (≥3 unitates)

Classis B (Installatio Recommandata):

Transformator capacitas 10× rating inversoris (impedimentum <4%)

Ratiocinatio inaequalitatis voltatium: 1.8–3%

Classis C (Installatio Optionalis):

Systemata cum compensatione potentiae reactivae (antiresonantia necessaria)

Alimenta cablum longum (100 m)

Installation Guidelines

Distancia ad inverterem: <5 m (ad minimas effectus inductantiae lineae)

Spatium a capacitoribus: ≥3× longitudinem apparatus

Optimanda sunt pro frequentia commutationis IGBT (typice 2–8 kHz)

Caracteristicae Protectionis

SensOREs interni temperatura (85°C alarmum, 105°C excursio)

Classis isolationis: F (155°C)

Formula dimensionANDi: L min = (2π⋅f⋅ΔIΔU)⋅K (ΔU: voltagium fluctuationis permittendum, f: frequentia fluctuationis, ΔI: currus fluctuationis permittendus, K: factor securitatis 1.2–1.5)

Prospectus operationis:

Diminuit currentem harmonicum input per 40–60%

Diminuit amissos thermicos condensatoris per 15–25%

Conformis normis IEEE 519-2014 pro mitigatione harmonicarum.

Plura producta

  • Ventilator axialis 630FZL2 Ventilator Industrialis ventilator electricus

    Ventilator axialis 630FZL2 Ventilator Industrialis ventilator electricus

  • BWDK-3206A Temperature Controller siccae BWDK-3206A

    BWDK-3206A Temperature Controller siccae BWDK-3206A

  • Conversor temperaturae TC420

    Conversor temperaturae TC420

  • Indicatore di temperatura trasformatore immerso in olio BWY-P802

    Indicatore di temperatura trasformatore immerso in olio BWY-P802

Cape Citatio Libera

Legatus noster te statim contactum faciet.
E-mail
Nomen
Producta intentata
Nomen companiae
Nuntius
0/1000

Cape Citatio Libera

Legatus noster te statim contactum faciet.
E-mail
Nomen
Producta intentata
Nomen companiae
Nuntius
0/1000

Cape Citatio Libera

Legatus noster te statim contactum faciet.
E-mail
Nomen
Producta intentata
Nomen companiae
Nuntius
0/1000